WaterSolve partnered with a dredging contractor at a Delaware chemical plant to remove and dewater settling pond sediment. Using a belt press and Solve 137 polymer, the team optimized performance, reduced water content, and prepared residuals for safe landfill disposal.
DOWNLOAD PDF Applications & ProductsGeotextile Tube Containers, DewateringServicesTurnkey Project ManagementIndustryIndustrialLocationDelaware
A dredging contractor was contracted to dredge the sediment from this Delaware based chemical plant’s wastewater settling pond. The pond residual was to be dewatered with a belt press and the solids loaded on trucks for subsequent hauling to a landfill. The dredge pumped the residual to a mixing tank for a more consistent flow of solids to the belt press. WaterSolve LLC was contracted to supply a chemical feed system, emulsion polymer, and technical support to monitor the polymer feed rate on the belt press for optimum performance.
A representative sample of the pond sediment was sent to WaterSolve’s lab prior to the project. Dewatering polymers were evaluated based on water release rate, water clarity, and flocculent appearance. In addition, dosing rate(s) were determined during bench-top dewatering experiments and recommendations provided to the facility during this phase of the program. Solve 137 was the recommended polymer for dewatering this residual on the belt press. WaterSolve successfully ran tests using Solve 137 with the pond residual using a belt press simulator in the lab. The belt press rental company then tested the Solve 137 on their simulator with the pond residual and approved the process. The dry wt solids of the belt press simulator were 56%.
A hydraulic dredge was placed in the wastewater settling pond to pump the pond residuals to a mixing tank. The mixing tank was filled to capacity, and the belt press dewatered the pond residuals one tank full at a time. A WaterSolve technician monitored and adjusted the polymer feed rate for optimum performance during the pressing operation. Adjustments were also made to the residual feed rate, the belt speed, and the pressure for the belt tension to optimize the performance of the press. The WaterSolve technician gathered a sample from each load of solids, measured the dry weight solids, and documented each load as they were filled. The dry tons for each load were calculated, and a running total was listed as part of the reporting each day. The dredge pumped approximately 500-GPM. The press operated at 100 to 200-GPM depending on the in-line density of the solids. Loads leaving the site averaged 55% dry wt solids and contained 11 dry tons of the pond residuals.